ENGLISH
- 47 -
Error 8
Whenexecutingaself-learningfunctionthecontrolisrefusedand
thedisplayshowsErr8
Itmeansthatthesettingofthecontrolunitisnotcompatiblewith
therequestedfunction.
Inordertocarryoutself-learning,theStartinputsmustbe
enabled in standard mode (Strt menu set to StAn) and the
ADIinterfacemustbedisabled(i.Adi menu set to no).
Tosurveythecurrentsofthemotoritisalsonecessarythatthe
lengthoftheopeningandclosureareatleastof7,5second.
Error 9
Whenyouaretryingtochangethecontrolunitsetupsandthethe
displayshowsErr9
Itmeansthatprogrammingwaslockedbymeansofthe
programminglockkeyCL1+(code161213).
Tochangethesettingsitisnecessarytoinsertintheconnectorof
theADIinterfacethesamekeyusedtoactivatetheprogramming
lock, and unlock the device.
Error 10
Whenastartcommandisgiven,thegatedoesnotopenandthe
displayshowsthemessageEr 10
ThismeansthattheADImodulefunctiontestfailed.