Fault codes and software
24h on-call service phone: +358 (0)40 83 71 150
40
4
• The card description for OPTCI (Ethernet option board) is changed to be able to do
the IP addressing using keypad. The parameters are visible automatically in the
Expander boards menu.
• The support and card description for new option board OPTAL. The option board
contains 6 numbers of 42...240VAC digital inputs in addition to 2AI, 2AO, 1DO.
More information will be updated in the next release of option board manual.
• Monitoring variables are added for the option board OPTAK (sine cos encoder
board).
• Customer specific option board descriptions are added.
• SBLastID parameter is added for option boards OPTD1 and OPTD2 for Vacon system
bus communication. This is only needed when drives with Vacon drive synch tech-
nology are used. The default value is zero and is suitable for general applications
without Vacon drive synch.
• Improvements for NC Drive CAN communication during signal monitoring. The ben-
efits can be seen with newer release than NCDrive 2.0.10.
10. 3. 3. 17. NXP00002V173
Replaced version: NXP00002V172.VCN
System software version: 12.51.9476 (VB00251)
System software version: 22.24.9542 (VB00561 / VB00661)
Changes in system software:
• Flying start function found not working with the recent developments in system
software NXP00002V172.(previous version). The error is now fixed in system soft-
ware NXP00002V173. The NXP00002V172 software is to be replaced by
NXP00002V173 wherever flying start is to be used.
10. 3. 3. 18. NXP00002V174
Replaced version: NXP00002V173.VCN
System software version: 22.24.9542 (VB00561 / VB00661)
System software version: 22.24.9542 (VB00561 / VB00661)
Changes in system software:
• New improved I2T algorithm implemented for FR7 & FR8, 500 V drives only.
• Improvements in input phase supervision.
Application changes:
• Basic (ASFIFF01) Version 4.02
• Standard (ASFIFF02) Version 4.02
• Local/Remote Control (ASFIFF03) Version 4.02