Fault codes and software
email: service@vacon.com Tel: +358 (0)201 212 575 Fax: +358 (0)204 335 091
41
4
Multi-step Speed Control (ASFIFF04) Version 4.02
PID Control (ASFIFF05) Version 4.02
Multi-purpose (ASFIFF06) Version 4.02
Multi-purpose (ASFIFF06) Version 4.02
Pump and Fan (ASFIFF07) Version 4.02
Motor current signal, that can be connected to analog output, was earlier connected
to the unfiltered current signal. This gave unnecessary variations in the Analog Out-
put. This has been changed to filtered value for more stable display. (Parameters
P2.3.5.2, P2.3.6.2 and P2.3.7.2, option 4 = O/P Current).
All applications are compiled with firmware interface version 4.58.
Additional changes in Multpurpose (APFIFF06) Version 2.17:
It is now possible to use two PT100 boards (OPTB8 simultaneously).
Following parameters have been added for the additional temperature measure-
ment channels:
P2.7.37 PT100 2 Numbers
P2.7.38 PT100 2 Warning Limit
P2.7.39 PT100 Fault Limit
Temperatures of the second board can be read from the following monitor values:
V1.21.25 PT100 4 Temp
V1.21.26 PT100 5 Temp
V.1.21.27 PT100 6 Temp
New option added for parameter P2.7.36 which defines Safe Disable mode. The new
option (0=WngNotStored) will not store Safe Disable warning to the history if the
previous warning in the history is the same.
When response of the “under voltage fault” (P2.7.5) was chosen to be “1 = No His-
tory”, the fault was still written to history. Now the option “1 = No History” will not
write the fault to history. This way we can avoid the unnecessary filling of fault his-
tory if required.
TABLE 15.
I/O monitoring support to NX option boards
NXOPT A-series NXOPT B-series NXOPT C-series NXOPT D-series
A1 B1 C2 D1
A2 B2 C3 D2
A3 B4 C4 D6
A4 B5 C5 D7
A5 B9 C6
A7 BA C7
A8 BB C8
A9 BC CF
AB BE CG

Table of Contents

Other manuals for Vacon NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX and is the answer not in the manual?

Vacon NX Specifications

General IconGeneral
Product TypeAC Drive
Control MethodScalar Control
EnclosureIP00, IP21
CommunicationEthernet
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Ambient Temperature Range-10°C to +50°C (with derating above +40°C)
Cooling MethodAir-cooled, Liquid-cooled

Related product manuals