Fault codes and software
24h on-call service phone: +358 (0)40 83 71 150
78
4
F44 Device Parameter change
INDICATION ONLY
F44 displayed.
Check
subcode.
Use old parameters?
NOTE:
Read Service Bulletin 0303. Available in NXSV128 / NXPV122 or newer. Copy
parameters to panel or PC before pressing reset. After pressing reset, drive will use
default parameters. F44 appears when power unit of different size or voltage is
connected to same control unit. F44 appears if new option board is of different type.
1: Control board
2: Control unit
3: Power board
4: Power unit
5: Adapter board
A: Slot A
B: Slot B
C: Slot C
D: Slot D
E: Slot E
Press reset.
Drive will now have default
parameters. Set needed
parameters.
YES
NO
Store parameters to
panel or PC. Press
reset.
Download
parameterset to
drive.
Drive will now have
downloaded parameters.
Check the most critical
parameters before entering
RUN mode.
FIGURE 37. Fault code F44

Table of Contents

Other manuals for Vacon NX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon NX and is the answer not in the manual?

Vacon NX Specifications

General IconGeneral
Product TypeAC Drive
Control MethodScalar Control
EnclosureIP00, IP21
CommunicationEthernet
SafetySTO (Safe Torque Off)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Ambient Temperature Range-10°C to +50°C (with derating above +40°C)
Cooling MethodAir-cooled, Liquid-cooled

Related product manuals