0020308121_04 Installation and maintenance instructions 31
Option 2: 24 V room thermostat
X31
X32
X41X36
X
2
X24
X20
X100
A 24 V room thermostat is connected to this interface and
used to transmit the switching signal.
7.10.9.1.3 Smart room controls
Smart room controls are available when an eBUS room con-
trol and a suitable Vaillant gateway are present. The room
control can be set and operated using the Vaillant app. For
connection, follow the instructions in the enclosed installation
instructions.
7.10.9.2 Weather-compensated control
A room control responds only indirectly to the weather condi-
tions. On the other hand, a weather-compensated control re-
sponds directly to the weather conditions. Using an outdoor
temperature sensor, the heat generator is operated depend-
ing on the outdoor temperature according to requirements.
Weather-compensated controls are eBUS controls. The out-
door temperature sensor is also connected to the PCB using
a connection plug. For connection, follow the instructions in
the enclosed installation instructions.
A weather-compensated eBUS control can also be intelli-
gently set and operated in conjunction with a Vaillant gate-
way and the relevant Vaillant app.
7.10.9.3 Control modules
The heat generator can be combined with various control
modules. Control modules are necessary if the installation
comprises an external 3-port valve, buffer cylinder, etc. For
installation and operation, follow the instructions in the en-
closed installation and operating instructions.
7.10.9.4 myVAILLANT Connect (VR 940f)
communication unit (Gateway)
A gateway enables remote communication between the user
and heat generator. The gateway can be connected to this
product via a special external interface.
Power supply and eBUS communication take place directly
via this interface. After installation, there is the option to set
and operate the control using the Vaillant app. Certain mod-
els can also be combined with other smart home solutions.
For installation, see the communication unit's installation
instructions.
7.10.9.5 sensoROOM pure (VRT 50/2)
The sensoROOM pure (VRT 50/2) is an eBUS room control.
If this control is combined with this heat generator, it is pos-
sible to configure time periods using the control display; to
do so, see the heat generator's operating instructions.
Note
If a sensoROOM pure (VRT 50/2) is connected,
the flow temperature must be set on the room
temperature control and, if required, the heating
mode must also be switched off there.
7.11 Installing the front casing
1.
A
C
D
B
2. Tighten the two screws on the left and right on the un-
derside of the product.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaillant ecoTEC plus VUI Series and is the answer not in the manual?

Vaillant ecoTEC plus VUI Series Specifications

General IconGeneral
BrandVaillant
ModelecoTEC plus VUI Series
CategoryBoiler
LanguageEnglish

Related product manuals