5.2.5. Casing
Degree of protection (IEC 60529) IP20
Dimensions (W x H x D) 209 x 155 x 223 mm
Material 1 mm steel plate
Weight 4.2 kg
Color code RAL 7032 (Casing) / RAL 7035 (Back plate)
5.2.6. Package
Dimensions (W x H x D) 215 * 160 * 275
Weight (Relay, Package and Manual) 5.2 kg
5.3. Disturbance recorder (DR)
The operation of Disturbance recorder depends on the following settings.
The recording time and number of records depend on the time setting and
number of selected channels.
Disturbance recorder (DR)
Mode of recording: Saturated / Overflow
Sample rate:
- Waveform recording
- Trend curve recording
32/cycle, 16/cycle, 8/cycle
10, 20, 200 ms
1, 5, 10, 15, 30 s
1 min
Recording time (one record)
0.1 s – 12 000 min
(must be shorter than MAX time)
Pre trigger rate 0 – 100%
Number of selected channels 0 – 12