Description of the Service Mode
Diagnosis, pressure
Statuses on the left side
Use Unit
Unlocked
Status of limit switch
S6
112P, 211P,
311P
Locked
Status of limit switch
S7 and S21
112P > S7
211P, 311P >
S7 + S21
Pressure
mode
Informs on the status
of the pressure
machine:
Stand-by
Preheating
Regulation
Decompression
Error
112P, 211P,
311P
Statuses right side
Use Unit
Unlocked
Status of limit switch
S18
112P
Locked
Status of limit switch
S7
112P
Pressure
mode
Informs on the status
of the pressure
machine:
Stand-by
Preheating
Regulation
Decompression
Error
112P
IV.11
v03 • July-2016 • Hen
Service Mode Module
Line Units Serial number (starting from) Sw Revision
VCCM
VCCWE
All ExxXH1009xxxxxxx 01-00-08