MAINTENANCE  Series 
 
96/116
Edition 2018-08-20  605262EE
 
Description 
Required tool 
15.  Assemble mechanical unit in reverse order as 
disassembled (steps 6 to 5). 
 
 
 
 
 
 
 
 
16. 
Align pedestal parallel to valve body and tighten 
the 2 mounting screws with 2.5 Nm. 
 
 
 
 
17. Center plate. 
Allen Wrench 
3 mm 
 
Adequate 
feeler gauge 
Size  Feeler gauge mm 
63  0.04 
80  0.06 
100  0.06 
200  0.08 
18.  Tighten plate screws with 2 Nm. 
19.  Assemble control and actuating unit to valve 
unit. Tighten mounting screws adequately. 
 
Allen Wrench 
 mm 
20.  Tighten clamp coupling: 
•  with elastic coupling 1.1 Nm 
•  with steel coupling 2.2 Nm 
 
Allen Wrench: 
 
elastic coupling
2 mm 
 
steel coupling 
2.5 mm 
 
Actuator side