984360EC Edition 12.08.2022 45/149
5.12.4.6 Samples:
command
response
Open: Control Mode to 4
p:010F0200000004
p:00010F0200000004
service
parameter
Index
value
01 (set)
0F020000
00
04
error
service
parameter
Index
value
00 (successfully)
01 (set)
0F020000
00
04
Position Control: Control Mode to 2
p:010F0200000002
p:00010F0200000002
service
parameter
Index
value
01 (set)
0F020000
00
02
error
service
parameter
Index
value
00 (successfully)
01 (set)
0F020000
00
02
Target Positon to 70.0
p:01110200000070
p:0001110200000070.0
service
parameter
Index
value
01 (set)
11020000
00
70
error
service
parameter
Index
value
00 (successfully)
01 (set)
11020000
00
70
Get Actual Pressure
p:0B1210000000
p:000B121000000023.1
service
parameter
Index
0B (get)
12100000
00
error
service
parameter
Index
value
00 (successfully)
0B (get)
12100000
00
23.1