EasyManua.ls Logo

VAT 650 Series - Page 35

VAT 650 Series
94 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4“ - 10”), CC-Link
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
280672EB
2010-12-15
35/94
Operation:
Description / Mode Digit 1
Digit 2 Digit 3 Digit 4
PRESSURE CONTROL mode
P
POSITION CONTROL mode
V
Valve closed
C
Valve open
O
Closed / open interlock
(Valve closed / open
by digital input)
I
HOLD (position frozen) activated
H
ZERO running
Z
LEARN running
L
Safety mode established. Refer to
«Safety mode» for details.
D
Power failure
F
0 . . . 100
= valve position (%, 0 = closed / 100 = open)
Service request
1)
S R
Cluster address information
MA
= Master
SL
= Slave
0 . . . FE
hex
= cluster address
Freeze mode
FROZ
= valve frozen
1)
SR is blinking alternatively with the actual mode display (e.g. C SR)
Errors:
Description Digit 1
Digit 2 Digit 3 Digit 4
Compressed air failure
(< 4 bar / 55 psi)
A I R f
Compressed air on exhaust
A I R x
Fatal error occurred
E
Error code. Refer to «Trouble shooting» for details

Table of Contents