Installation, Operating & Maintenance Instructions 
Series 650 DN 100-250 (I.D. 4“ - 10”), CC-Link 
 
 
 
VAT Vakuumventile AG, CH-9469 Haag, Switzerland 
Tel +41 81 771 61 61   Fax +41 81 771 48 30   CH@vatvalve.com www.vatvalve.com 
280672EB 
2010-12-15 
78/94 
 
Note: Electrical power and compressed air is required to perform steps 2 to 9 during disassembly respectively 9 to 2 
during assembly. 
 
D e s c r i p t i o n  Required tool 
   
1.  Vent both valve chambers.  
 
2.  Open the 4 bonnet screws and 
remove valve bonnet. 
 
 
 
 
Allen wrench 
5mm 
   
 
3. Open valve 
 
Caution: Stand away from valve – 
pendulum plate moves out of the 
valve body. 
 
4.  Unfasten mounting screw for 
pendulum plate. (For reinstall the 
pendulum plate, tighten the 
mounting screw to block.) 
 
5.  Remove pendulum plate. 
 
 
 
 
 mounting screw 
 for pendulum plate 
 
 
 
open end wrench
13mm 
   
6.  With one hand press the 
MAINTENANCE BUTTON to lower 
the sealing ring, with your second 
hand unlock the sealing ring by 
pressing the handle. 
 
7. Release MAINTENANCE BUTTON. 
 
8.  Remove sealing ring. 
 
9.  To prevent the shaft and retaining 
pins from moving during work, switch 
the valve to safety mode. Refer to 
«Safety mode» for details. 
 
Note: Retaining pins will move up. 
 
 
 
 
 maintenance button 
     
unlock