Installation, Operating & Maintenance Instructions 
Series 650 DN 100-250 (I.D. 4“ - 10”), CC-Link 
 
 
 
VAT Vakuumventile AG, CH-9469 Haag, Switzerland 
Tel +41 81 771 61 61   Fax +41 81 771 48 30   CH@vatvalve.com www.vatvalve.com 
280672EB 
2010-12-15 
83/94 
 
D e s c r i p t i o n  Required tool 
   
 
39.  If necessary adjust pendulum plate: 
 
a.  Move pendulum plate a little towards 
open (e.g. position 1% of full stroke) 
 
b.  Use adjustment screw at flange side 
of actuator (1 turn clockwise adjusts 
pendulum plate by about 3mm 
towards open). 
 
c.  Restart valve in menu 
‘System/Recovery’ 
 
d.  Check pendulum plate position 
according step 38 and redo 
adjustment procedure if necessary. 
 
Adjusting screw mounted either in actuator 
position «B1 standard» or «B2 option»  
 
 
 
 
 
Allen wrench 
2mm 
 
 
 
40.  Clean the valve sealing surface 
 
 
 
Lint-and dust-
free towel a little 
soaked with 
isopropyl alcohol
   
41.  Clean the valve bonnet o-ring 
 
 
 
Lint-and dust-
free towel 
   
 
42.  Mount valve bonnet. 
•  Tightening torques for bonnet 
screws, see in table to the right. 
 
Max. torque 6 Nm 
Allen wrench 
5mm