RS-232 Commands Function Code: 201
29
Function Code: 201
Function Type: In-Tank Inventory Report Version 1
Command Format:
Display: <SOH>I201TT
Computer: <SOH>i201TT
Typical Response Message, Display Format:
<SOH>
I201TT
TANK HEIGHT WATER TEMP
1 48.9 0.0 37.3
<ETX>
Typical Response Message, Computer Format:
<SOH>i201TT0000000000TT0ssssNNFFFFFFFF...
TTpssssNNFFFFFFFF...&&CCCC<ETX>
Notes:
1. 0000000000 - Unused
2. TT - Tank Number (Decimal, 00 = all)
3. 0 - Unused
4. ssss - Tank Status Bits:
Bit 1 - (LSB) Unused
Bit 2 - Unused
Bit 3 - Invalid Fuel Height Alarm (MAG Probes Only)
Bit 4-16 - Unused
5. NN - Number of eight character Data Fields to follow (Hex)
6. FFFFFFFF - ASCII Hex IEEE float:
1. Unused
2. Unused
3. Unused
4. Height
5. Water
6. Temperature
7. Unused
7. && - Data Termination Flag
8. CCCC - Message Checksum