EasyManua.ls Logo

Veeder-Root TLS-HLD - Function Code: A01; Probe Type and Serial Number

Veeder-Root TLS-HLD
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RS-232 Commands Function Code: A01
41
Function Code: A01
Function Type: Probe Type and Serial Number Version 1
Command Format:
Display: <SOH>IA01TT
Computer: <SOH>iA01TT
Typical Response Message, Display Format:
<SOH>
IA01TT
TT PP KKKK LLLL.LL SSSSSS cccc
<ETX>
Notes:
1. TT - Tank Number (Decimal, 00 = all)
2. PP - Probe Type: - MAG1
3. LLLL.LL - Probe Length (Decimal)
4. SSSSSS - Probe Serial Number (Decimal)
5. cccc - Probe Date Code (Hex)
Typical Response Message, Computer Format:
<SOH>iA01TT0000000000TT0PPKKKKFFFFFFFFSSSSSScccc...
TT0PPKKKKFFFFFFFFSSSSSScccc&&CCCC<ETX>
Notes:
1. 0000000000 - Not Used.
2. TT - Tank Number (Decimal, 00 = all)
3. 0 - Not used
4. PP - Probe Type: 03 = MAG1
5. KKKK - Circuit Code (Hex)
6. FFFFFFFF - Probe Length (ASCII Hex IEEE float)
7. SSSSSS - Probe Serial Number (Decimal)
8. cccc - Probe Date Code (Hex)
9. && - Data Termination Flag
10. CCCC - Message Checksum

Table of Contents