EasyManua.ls Logo

Veeder-Root TLS-HLD - A11 Probe Fast Average Buffers; Function Code: A11

Veeder-Root TLS-HLD
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
RS-232 Commands Function Code: A11
Function Code: A11
Function Type: Probe Fast Average Buffers Version 1
Command Format:
Display: <SOH>IA11TT
Computer: <SOH>iA11TT
Typical Response Message, Display Format:
<SOH>
IA11TT
TT PP nnnnn
ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss
ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss
ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss ssss.sss
ssss.sss ssss.sss
<ETX>
Notes:
1. TT - Tank Number (Decimal, 00 = all)
2. PP -Probe Type:03 - MAG1
3. nnnnn - Sample Number (Decimal)
4. ssss.sss - Probe Data (Decimal)
Typical Response Message, Computer Format:
<SOH>iA11TT0000000000TT0PPSSSSNNFFFFFFFF...
TT0PPSSSSNNFFFFFFFF...&&CCCC<ETX>
Notes:
1. 0000000000 - Not Used
2. TT - Tank Number (Decimal, 00 = all)
3. 0 - Not used
4. PP - Probe Type: 03 - MAG1
5. SSSS - Number of Samples (Hex)
6. NN - Number of eight character Data Fields to follow (Hex)
7. FFFFFFFF - Probe Data (ASCII Hex IEEE float)
8. && - Data Termination Flag
9. CCCC - Message Checksum

Table of Contents