RS-232 Commands Function Code: 882
37
Function Code: 882
Function Type: Initialize Communication Port Data Version 1
Command Format:
Set:
Inquire:
Display: <SOH>S882CC149 Display: <SOH>I882CC
Computer: <SOH>s882CC149 Computer: <SOH>i882CC
Notes:
1. 149 - This verification code must be sent to confirm the command
Typical Response Message, Display Format:
<SOH>
I882CC
CC BBBBB P S D T AA
<ETX>
Typical Response Message, Computer Format:
<SOH>i882CC0000000000CCBBBBBPSD0AA&&CCCC<ETX>
Notes:
1. 0000000000 - Not Used.
2. CC - Communication Port Number (1)
3. BBBBB - Baud Rate (Decimal)
4. P - Parity (Decimal; 0= None, 1 or 2)
5. S - Stop Bit (Decimal; 1 or 2)
6. D - Data Bit (Decimal; 7 or 8)
7. 0 - Not Used
8. AA - Number of Rings before Answer (Decimal)
9. && - Data Termination Flag
10. CCCC - Message Checksum