RS-232 Commands Function Code: 517
33
Function Code: 517
Function Type: Set System Type & Language Flags Version 1
Command Format:
Set:
Inquire:
Display: <SOH>S51700ULL Display: <SOH>I51700
Computer: <SOH>s51700ULL Computer: <SOH>i51700
Typical Response Message, Display Format:
<SOH>
I51700
U
LL
<ETX>
Typical Response Message, Computer Format:
<SOH>i517000000000000ULL&&CCCC<ETX>
Notes:
1. 0000000000 - Not Used.
2. U - System Units:
1 = U.S
2 = Metric
3. LL - System Language:
1 = English
2 = French
3 = Spanish
4 = Not Used
5 = Portuguese
6 = Not Used
7 = Not Used
8 = Not Used
9 = Not Used
10 = Not Used
11 = Not Used
12 = Not Used
13 = Not Used
14 = Not Used
15 = Chinese
4. && - Data Termination Flag
5. CCCC - Message Checksum