GENERAL OPERATION
Daily Inspection
WARNING
Always engage the parking brake, shut o the pow-
er unit engine, remove the ignition key, and ensure
that all moving parts have come to a complete stop
before inspecting the components, or attempting
any repair or adjustment.
1. Park the machine on a level surface, with the en-
gine shut o and all uids cold.
2. Perform a visual inspection of the power unit.
Look for loose or missing hardware, damaged
components, or signs of wear.
3. Inspect the ROPS structure and seat belt for dam-
age or signs of wear.
4. Inspect the battery, the electrical connections, and
the lights.
5. Ensure the parking brake is set to the proper ten-
sion. Adjust the tension as required.
6. Inspect the hydraulic hoses and the hydraulic t-
tings to ensure tight, leak free connections.
7. Inspect the fuel lines to ensure tight, leak free
connections.
8. Inspect the belts for damage or excessive wear.
Refer to the Belt Inspection section of this manual.
9. Check the power unit’s engine oil level, the hy-
draulic oil level, the coolant level (if equipped), and
the fuel level. Add uid or service as required.
ATTENTION
If the power unit is equipped with a cab and heater
kit and the outside air temperature is 4° C (40° F)
or above, the radiator bae must be removed and
replaced with the radiator screen.
10. Ensure the radiator screen (if equipped), the air
cleaner, and the engine compartment are clean.
11. Check the tires for proper ination.
12. Test the operator safety interlock system.
Starting the Engine
CAUTION
Use of ether or starting uids may cause engine
damage and/or personal injury. Do not use ether or
starting uids to aid in starting the engine.
The 4500 is equipped with an interlock system for op-
erator safety. The safety interlock system requires the
parking brake to be engaged and the SDLA lever to be
in the neutral position for the power unit to start.
1. Turn the fuel shut-o valve to the On position.
2. Turn the battery disconnect switch to the On posi-
tion.
3. Move the throttle lever to the half throttle position.
ATTENTION
Do not run the electric starter continuously for more
than 5 seconds. If the engine does not start in this
time, wait 15 seconds and try again.
4. Turn the ignition key to the start position and hold
to engage the starter. Release the key when the
engine starts. NOTE: if engine fails to start, refer
to the troubleshooting section.
ATTENTION
Allow time for the hydraulic oil to circulate before
operating the power unit. Failure to allow adequate
warm up time may result in severe damage to the
hydraulic system. Warm up time is increased in
colder weather.
5. The engine and hydraulic oil must be warmed up
before operating. Allow the power unit to run at
approximately 1,800 rpm until the hydraulic lter
is warm to the touch. The lter is located below
the front fuse panel to the left of the dash.
https://www.tractormanualpdf.info/

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ventrac 4500P and is the answer not in the manual?

Ventrac 4500P Specifications

General IconGeneral
BrandVentrac
Model4500P
CategoryUtility Vehicle
LanguageEnglish

Related product manuals