25
VX 805 CTLS INSTALLATION G
UIDE
CHAPTER 3
Specifications
This chapter discusses power requirements, dimensions, and other specifications
of the VX805 CTLS.
Unit Power
Requirements
• Input voltage: 5V-12V DC
• USB Power, minimum 5 V, 500mA (without Ethernet)
Power Pack • PWR282-001-01-A (varies per region)
• UL, ITE listed, Class 2, switching power supply
• PS, 100-240V, 9V DC UNIVERSAL, 1A, 9W
Temperature • Operating temperature: 0° to 40° C (34° to 104° F)
• Storage temperature: -20° to 60° C (-4° to 140° F)
• Relative humidity: 5% to 90% RH non-condensing
External
Dimensions
• Length : 158 mm (6.22 in.)
• Width: 83.1 mm (3.27 in.)
• Depth: 31.4 mm (1.24 in.)
Weight • Unit weight: 0.27 Kg (0.6 lbs.)
• Shipping weight: 0.45 Kg (1.0
lbs.)
Processor • 400 MHz ARM11 32-bit RISC processor
Memory • 160 MB (128 MB of Flash, 32 MB of mDDR)
Display • 128x64 FSTN
Magnetic
Card
Reader
• Triple track (tracks 1, 2, 3), high coercivity, bi-directional
Primary Smart Card • ISO 7816, 1.8V, 3V, 5V
• synchronous and asynchronous cards
• EMV Approved
SAM Card Reader • 2 Security Access Modules (SAMs)