Integral Cab Header Installation LD-16 Door Operator - Modernization
22 © Vertical Express
Single-Speed Center-Opening Doors Integral Cab Header Installation
(continued)
Figure 17 - Modify Header and Install Mounting Angles
Figure 18 - Relationship of Keyslots and Door Operator Machine to Clear Opening
Remove Part of the Header (if necessary)
for Clearance of the Mounting Angles
21" ± 2"
Mounting Angle
21" from Center of Opening
Center of Door Opening
Mounting Angle
21" from Center of Opening
21"
32"(for door widths up to 60")
42" (for door widths up to 60")
Keyslots shown at 42'' are primary locations to brace the operator back to the cab.
Other keyslot locations may be used where interference prohibits mounting angles.
2½"
2½"
B
A
Clear Opening B A
32 64 63½
34 68 67½
36 72 71½
38 76 75½
40 80 79½
42 84 83½
44 88 87½
Clear Opening B A
46 92 91½
48 96 95½
50 100 99½
52 104 103½
54 108 107½
56 112 111½
58 116 115½
60 120 119½
All
dimensions
in inches