Circuit open or short circuit to negative:interruption of the circuit or null voltage between control unit
connector PIN 11 and 12.
Troubleshooting
Short circuit to positive:
- Disconnect the control unit connector and the sensor connector.
- Verify that there is no short to battery positive on sensor connector PIN 3 (corresponding to control
unit connector PIN 11); in the presence of short circuit, restore the cable harness.
- Verify that there is no short to battery positive on sensor connector PIN 4 (corresponding to control
unit connector PIN 12); in the presence of short circuit, restore the cable harness.
Open circuit:
- Disconnect the control unit connector and the sensor connector.
- Check the continuity of the cable harness between the sensor connector and control unit connector:
Control unit PIN 11 - sensor PIN 3 and control unit PIN 12 - sensor PIN 4. If necessary, restore the
cable harness.
- If the cable harness is intact and the error persists, proceed with the following checks.
Short circuit to negative:
- Disconnect the sensor connector and the control unit connector.
- Check the sensor connector PIN 3 from ground insulation. If there is no insulation, restore the cable
harness.
- Check the sensor connector PIN 4 from ground insulation. If there is no insulation, restore the cable
harness.
- If PIN 3 and PIN 4 are insulated from the ground and the error persists, this means that there is a
probable fault in the control unit.
P0135 Lambda probe heating - shorted to positive / shorted to negative / open circuit.
Error cause
Shorted to positive: excessive voltage at PIN 31 of the control unit connector.
Shorted to negative: lack of insulation from ground on the sensor connector PIN 1.
Open circuit: circuit interruption.
Troubleshooting
Shorted to positive:
- Disconnect the control unit connector and the sensor connector.
- Verify that there is no short to battery positive on sensor connector PIN 2 (corresponding to control
unit connector PIN 31); if there is a short, restore the cabling.
Open circuit:
- Disconnect the control unit connector and the sensor connector.
- Check continuity of the cabling between the sensor connector and the control unit connector: control
unit PIN 31 - sensor PIN 2. Restore the cabling if necessary.
Vespa LX - S 125 3V ie 150 3V ie (2012) Electrical system