4 options will be displayed:
GROUPS SET POINT
Use the rotary switch to select the coffee group to
adjust and confirm by pressing it.
Set the temperature for each single group.
We recommend setting the temperature for the
groups and coffee boilers at the same value,
except in special cases where you want to obtain
very specific results.
Generally mixtures with good percentage of robust
prefer temperatures below 90°, while 100% Arabic
is able to express the best characteristics with
temperatures above 90°.
COFFEE BOILER TEMPERATURE
To adjust the temperature of the coffee boiler
return to the previous screen by pressing the
menu button.
BOILER SET POINT
The display shows:
Select the coffee boiler to be adjusted and con-
firm by pressing the rotary switch.
Heater 1 example:
Turn the rotary switch to select the required tem-
perature for the group, then press it to confirm.
Edition 01 of 08/2017
2.11
SERVICE MANUAL
Setpoint
Group
setpoint
Boiler
setpoint
Steam boiler
setpoint
Cup warmeroiler
t
oin
am b
t
oin
St
s
rou
set
B
s
warmer
ile
Fig. 34
Group setpoint
Group temperature
Group setpoint
93.8
94.0
93.0
93.8
93.093.2
Fig. 35
Boiler setpoint
Boiler temperature
Boiler setpoint
93.493.4
92.0
93.4
92.092.0
Boiler set
o
Fig. 36
Boiler setpoint
Boiler temperature
Boiler setpoint
93.894.0
93.0
93.8
93.093.2
3
Fig. 37
Instant
value
Set