12
Use the A & B key to navigate through the pre-programmed messages.
Press the * key to return to the Administration Menu.
3.1.5 Coverage Test Menu
From the Administration Menu, select 5 followed by the # key. Enter a value between 1 and 8 to determine the cover
page interval:
1 – Every 5 seconds
2– Every 10 seconds
3 – Every 15 seconds
4 – Every 20 seconds
5 – Every 30 seconds
6 – Every 1 minute
7 – Every 2 minutes
8 – Every 4 minutes
Use this option to send cover page to device 100. This feature is useful when testing the transmitter coverage area.
Press * to cancel and return to the Administration Menu.
3.1.6 Time Zone Setup Menu
From the Administration Menu, select 6 followed by the # key. The following screen will be displayed:
TIME ZONE SETUP:
06
Enter the offset in hours of the local time zone from UTC (Universal Coordinate Time) or GMT (Greenwich Mean Time) time.
Use 01 to 23 for negative offset (GMT -1 to GMT -23), 00 or 24 for GMT time, 25 to 47 for positive offset (GMT+1 to
GMT+23).
For examples, for the following time zones, enter the following values:
Eastern Time: 05
Central Time: 06
Mountain Time: 07
Pacific Time: 08
Alaska Time: 09
Hawaii Time: 10
After the last step is completed, the display will return to the Administration Menu.
3.1.7 Last Message Menu
From the Administration Menu, select 7 followed by the # key.
Use this option to display the last message sent to a device.
Press * to cancel and return to the Administration Menu.
3.1.8 Reset Database Menu
NOTE
: This is an IRREVERSIBLE command - DO NOT select this option unless you are absolutely sure you want to clear
all devices and pre-programmed messages data.
You may want to transcribe this information to paper first or use the optional PC software to backup the data to a computer.
From the Administration Menu, select 8 followed by the # key.
CLEAR ALL DATA..
ARE YOU SURE???
Press # to confirm the Database Reset. Press * or any other key to cancel and return to the Administration Menu.