14
8 – MC Sync Duration
Determines the Master Clock Synchronizer contact closure time interval (seconds). Enter a
value between 0 and 9 followed by # key to save the settings:
0
– Disabled
1 – 1 seconds
2 – 2 seconds
3 – 3 seconds
4 – 4 seconds
5 – 5 seconds
6 – 6 seconds
7 – 7 seconds
8 – 8 seconds
9 – 9 seconds
9 – Security Mode
Determines if secure data mode should be used. This provides data encryption to secure the
transmission to the wireless receivers using the security key. Enter a value between 0 and 9
followed by # key to save the settings:
0
– Disabled
1 – Mode 1
2 – Mode 2
3 – Mode 3
4 – Mode 4
5 – Mode 5
6 – Mode 6
7 – Mode 7
8 – Mode 8
9 – Mode 9
0 – Security Code
Determines the security key for secure data mode.
Enter a value between 0 and 299.
A – Schedule Paging
Indicates if the type and status of the event schedule. Enter a value between 1 and 3 followed
by # key to save the settings:
1
– Weekly
2 – Calendar
3 – Idle (standby mode)
Note: This setting is applicable only when the schedules events option was ordered and
installed on the VS4500.
B – Schedule Slot
Determines the active weekly Event Schedule.
Enter a value between 1
and 4 followed by # key to save the settings.
Note: This setting is applicable only when the schedules events option was ordered and
installed on the VS4500. The setting applies to weekly schedule only.
C – TX Deviation
Determines the TX deviation. Enter a value between 1 and 9 followed by # key to save the
settings:
1 – ±0.5kHz
2 – ±1.0kHz
3 – ±1.5kHz
4 – ±2.0kHz
5
– ±2.5kHz
6 – ±3.0kHz
7 – ±3.5kHz
8 – ±4.0kHz
9 – ±4.5kHz
D – Call Sign
Displays the call sign assigned to you by the FCC (if any). Contact Visiplex tech support for
more details.
Note: Underlined values indicate default values.
Press the * key to return to the Administration Menu.