VOLLMER WERKE
Operating instructions
Issue: 01
MAP 200 / 400
Page: 3-3
3.4.1 Electrical system
Work on the electrical system may only be carried out by suitably qualified electricians in accor-
dance with the electrical standards.
The electrical system must be checked at regular intervals, and any defects, e.g. loose cables or
plug connections, must be remedied immediately.
Only use original fuses with the specified rating.
3.4.2 Tools/tool change
Tool cutting edges can cause minor cuts. For this reason, pay particular attention to the clamped tool
when working on the machine.
3.4.3 Chemical substances and oils
When working with chemical substances and oils, always avoid contact with the eyes or inadvertent
swallowing. Where skin contact is unavoidable, treat hands beforehand with protective skin cream.
Also observe the safety information provided on the packaging or data sheets.
3.5 Intended purpose
This machine is a Machine for the automatic levelling of band saw blades and may only be used
for this purpose.
Any other use of the machine is deemed inconsistent with its intended purpose. The manufac-
turer is not liable for any resulting damage. Any risk arising from incorrect use is the sole re-
sponsibility of the user.
Application in accordance with the intended purpose also implies adherence to the operating and
maintenance conditions contained in the operating instructions.
All Vollmer systems are designed as self-contained units and are safety-inspected. If they are to be
used in wider applications, e.g. connection to central systems (e.g. central coolant supply, central ex-
traction system, etc.), the customer must ensure that the resulting overall system complies with the
relevant national safety requirements (e.g. EC conformity).
3.6 Note on special hazards
3.6.1 Hydraulic system, pneumatic system
Work on the hydraulic or pneumatic system may only be carried out by suitably qualified operating
staff.
All conductors, hoses and screw joints must be checked once a month for leaks and externally rec-
ognizable damage. Any defects discovered must be remedied without delay.
Oil leaking from the system can cause fire or injury.
When exchanging hydraulic or compressed air pipes, ensure that correct hose fittings are used,
that the pipes used are of sufficient length, and that they are mounted and laid correctly by suitably
qualified staff.
Observe the information provided on how to avoid confusion of connection points.
De-pressurise the pressure accumulator before the start of any repair work in accordance with the
assembly descriptions.