e) Setting the thermocouple type
A short press on the DOWN (5) indicates the thermocouple type setting.
To change the sensor type, press the ENTER (7) until MODE appears on the display and then press the DOWN (5)
repeatedly until the desired sensor type is selected. Press ENTER (7)toconrmuntilMODEisnolongerdisplayed.
f) Setting the thermocouple offset
A short press on the DOWN (5) indicates the offset setting.
To change the offset in probe type setting mode, press and hold the ENTER (7) until MODE appears on the display.
Nowthevaluecanbechangedby-0.1bybrieypressingtheDOWN (5) and by -1.0 by pressing and holding it down.
Thevalueisreducedto5.0andthenjumpsto5.0andcanbereducedto0.0.Toconrm,presstheENTER (7) until
MODE is no longer displayed.