Display 2000 counts (4000 counts with the VC170-1)
Measuring frequency approx. 2-3 measuring operations/second
Measuring lead length about 75 cm each
Measuring impedance >10MΩ (V range)
Operating voltage 9V block battery
Working conditions 0°C to 40°C max. 75% rF, non-condensing
Operating altitude max. 2,000 m
Storage temperature -10°C to +50°C
Weight ca. 200 g
Dimensions (LxWxH) 137 x 72 x 35 (mm)
Measuring category CAT III 250 V
Degree of contamination 2
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The accuracy is
valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than 75%, non-condensing.
Direct voltage, overload protection 250 V
200 mV
±(0.5% + 8)
0.1 mV 400 mV* ±(0,8% + 8) 0.1 mV
2,000 mV 1 mV 4,000 mV
±(0,8% + 8)
1 mV
20 V 0.01 V 40 V 0.01 V
200 V 0.1 V 250 V 0.1 V
250 V ±(0,8% + 8) 1 V * With the VC170-1, the 400 mV measuring range
is only available via the manual measuring range
selection.