Operation
Exhaust gas after-treatment
BA RC50_RC70 en 00
103
NOTICE
High gas temperature!
Property damage by fire during the parked regeneration of the diesel
particulate filter.
■
During park regeneration, prevent hot exhaust gases or the end
of the exhaust pipe from igniting objects in the vicinity (e.g. do not
perform the regeneration under trees or on dry grass).
■
Initiate park regeneration only in a safe place: firm, non-
combustible surface.
Initiating parked regeneration
Prerequisites:
■
Machine is at standstill,
■
Diesel engine is running,
■
Operating temperature has been reached,
■
The switch [3] flashes.
Push the drive lever [1] out of position 0 to the right and into position
P.
Set the engine speed [5] to idling (MIN).
Press switch [3].
a
The engine speed is automatically increased.
a
The parked regeneration starts.
a
The engine speed is automatically decreased once parked
regeneration is successfully completed.
NOTE
No operating functions may be activated during parked
regeneration (duration approx. 30 minutes). Only turn off
the diesel engine once parked regeneration is successfully
completed.
Parked regeneration must only be cancelled in cases of
emergency.
Cancelling parked regeneration
Move the drive lever [1] forwards or backwards.