Maintenance
Hydraulic oil supply
BA RD18 en 01
141
Also actuate the steering.
a
The pipes and hose lines will be filled with oil and vented.
Check oil level with the diesel engine at a standstill. Top up oil if
necessary.
Check hydraulic system for leaks.
4.04.03 Replacing the filter insert in the pressure filter for the hydraulic system
$ Only lubricants with this symbol are permitted ("Technical data",
page 161 onwards).
1
2
Switch off diesel engine and remove ignition key.
Allow machine to cool down less than 30 °C (86 °F).
Unscrew the barrel casing [1].
Unscrew the filter insert [2] from the filter head and replace with a
new one.
Clean the inside the barrel casing [1].
Screw in and tighten the barrel casing [1] in the filter head again.
Check hydraulic system for leaks.