Maintenance
Water sprinkling
BA RD18 en 01
155
31 2 4
Prerequisites
Diesel engine off
Electrical system on
Parking brake activated
For water sprinkling: Drive lever in F position (forward)
Checking the spray nozzles for the water-sprinkling system
Press switch [1].
a
Water sprinkling is done by intermittent operation at the preset
interval level.
Press and hold the foot switch [2].
a
The water sprinkler will be active as long as the foot switch is being
pressed.
Press the switch [1] again or release the foot pedal [2].
a
Water sprinkling off.
Latch driving lever in position 0.
Switch off the electrical system.
Checking the spray nozzles for the additive-sprinkling system
Press and hold the switch [3] or foot switch [4].
a
The additive sprinkler will be active as long as one of the switches is
pressed and held.
Release switch [3] or [4].
a
Additive sprinkling turned off.
Latch driving lever in position 0.
Switch off the electrical system.
NOTE
If the sprinkler does not work or does not produce the desired
sprinkling pattern, the sprinkler nozzles need to be cleaned.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson RD18 and is the answer not in the manual?

Wacker Neuson RD18 Specifications

General IconGeneral
BrandWacker Neuson
ModelRD18
CategoryConstruction Equipment
LanguageEnglish

Related product manuals