Operating manual Spray wall Basic 8000
4 Basic Safety Instructions
Order number 3305595 | Edition 07/2022 13
4 Grounding cables must be checked regularly to ensure that they are serviceable (see EN
60204).
4.2.4 Product Hoses
Danger due to damaged product hoses!
The product hose may cause dangerous injuries.
4 Use only an original WAGNER powder hose.
4 Make sure that the hoses are laid only in suitable places. Hoses should not be laid in the
following places under any circumstances:
4 in high traffic areas
4 on sharp edges
4 on moving parts
4 on hot surfaces
4 Ensure that the hoses are never run over by vehicles (e.g., fork lifts), or that the hoses
are never put under pressure from the outside in any other way.
4 Ensure that the hoses are never kinked. Observe maximum bending radii.
4 Ensure that no work is ever performed with a damaged hose.
4 Make sure that the hoses are never used to pull or move the device.
4.2.5 Electrical Connection Cables
Risk caused by improperly laid cables!
Risk of injury and damage to the device.
4 Properly lay connection cables and check them regularly.
4 Immediately replace damaged connection cables.
4 Ensure that no work is ever performed with a damaged connection cable.
4 Do not lay connection lines on travel paths of forklifts or through doors/gates.
4 Do not lay connection lines in the area of walkable hallways or paths to avoid the risk of
tripping.
4.2.6 Cleaning and Flushing
Danger due to cleaning and flushing!
Explosion hazard and damage to the device.
4 Before starting cleaning or any other manual work, the high voltage in the spray area
must be shut down and locked to prevent it from being switched back on.
4 Lock the compressed air supply and decompress the device.
4 Secure the device against being switched back on without authorization.
4 Use only electrically conducting and grounded tanks for cleaning fluids.
4 Preference should be given to non-ignitable cleaning fluids.
4 Ignitable cleaning liquids may only be used if all high-voltage parts are discharged to a
discharge energy of less than 0.24mJ after shutting off the high voltage before these
parts can be reached. Most ignitable solvents have an ignition power in the range of
0.24mJ, corresponding to 60nC.
4 The flash point of the cleaning agents must be at least 15K over the ambient
temperature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER Basic 8000 and is the answer not in the manual?

WAGNER Basic 8000 Specifications

General IconGeneral
BrandWAGNER
ModelBasic 8000
CategoryPaint Sprayer
LanguageEnglish

Related product manuals