28 LED display: "High Voltage"
Lights up yellow. The high voltage is selected and can be adjusted using rotary
controller 24
29 Push button: "Current Limitation"
To activate the function, the current limitation is set with the control dial 24 and is
indicated in the LED display 19
Adjusting range: 5-120 μA
Resolution: 1 μA
30 LED display: "Current Limitation"
Lights up yellow. The current limitation is selected and can be adjusted using rotary
controller 24
31 Push button: "Characteristic Slope"
To switch the characteristic slope
Display with LED 32
32 LED display: "Characteristic Slope"
Lights up green
Lower LED characteristic curve,  at
Middle LED characteristic curve, medium
Upper LED characteristic curve, steep
33 Illuminated display: "Powder Quantity"
Lights up green
Display range: 0-100%
Resolution: 3.33%
Single LED display: Set point (high voltage and powder are deactivated)
Bar display: Actual value (high voltage and powder are activated)
34 Illuminated display: "Total Air Volume"
Lights up green
Display range: 1-6 m³/h
Resolution: 0.2-0.5 m³/h
Single LED display: Set point (high voltage and powder are deactivated)
Bar display: Actual value (high voltage and powder are activated)
35 Illuminated display: "Atomizing, Ionizing and Tribo Air Volume"
Lights up green
Display range: 0.1-4 m³/h
Resolution: 0.1-1.0 m³/h
Single LED display: Set point (high voltage and powder are deactivated)
Bar display: Actual value (high voltage and powder are activated)