EasyManuals Logo

WAGNER EPG-SPRINT Original Service Manual

WAGNER EPG-SPRINT
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
66
EPG-SPRINT / EPG-SPRINT X
P_01276
P_01277
%
Tribo
Corona
5
4
3
2
1
120
100
80
60
40
30
20
15
10
5
μA
μA
0
10
20
30
40
50
60
70
80
90
100
Ø
12
10
11
9
8
m /h
5.0
4.0
3.0
2.0
6.0
3
5.5
4.5
3.5
2.5
2.2
kV
90
80
70
60
50
40
30
20
10
100
m /h
4.0
3.0
2.0
1.0
0.5
0.4
0.3
0.2
0.1
1.5
EPG
S
P
R
I
N
T
P_01270
33353420 21
EPG
SPRINT X
0
%
100
%
kV
80
60
40
20
100
Tri Cor
5
4
3
2
1
120
80
40
20
10
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
μA
P_01831
33353420 21
SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
Note:
This test can also be used as a function test for the gun cable. If the ground monitoring
circuit is interrupted, the LED bar 1 does not light up. A loose connection in the plug or gun
connection can also be detected by moving the cable.
Testing the 3 inputs of the CCM bushing for remote control:
1. Connect control unit CCM2007/CCM Prima with EPG-CCM cable (order No. 263214).
2. Press "Total Air Volume" button 20; 24 VDC is activated on pin 4 of the CCM bushing.
3. Switch on "System" and "Coating" on CCM control unit. "Total Air Volume" LED bar 34
lights up.
4. Press "Reset" button on CCM control unit. The "Powder Quantity" indicator 33 lights up.
5. Press "Coating Surface Parts" button on CCM control unit. "Atomizing Air" LED bar 35
ashes.

Table of Contents

Other manuals for WAGNER EPG-SPRINT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WAGNER EPG-SPRINT and is the answer not in the manual?

WAGNER EPG-SPRINT Specifications

General IconGeneral
BrandWAGNER
ModelEPG-SPRINT
CategoryControl Unit
LanguageEnglish

Related product manuals