33
B_00304
R max < 1 M Ω
OPERATING MANUAL
VERSION 02/2013 ORDER NUMBER DOC 2333548
6.4 GROUNDING
Grounding scheme (example)
Pump
Paint container
Work piece
Conveyor
Spraying stand
Floor, electrostatically conductive
Heavy paint mist if grounding is insu cient!
Danger of poisoning.
Insu cient paint application quality.
Ground all device components.
Ground the work pieces to be coated.
WARNING
Discharge of electrostatically charged components in
atmospheres containing solvents!
Explosion hazard from electrostatic sparks.
Clean the piston pump only with a damp cloth.
Ground all device components.
Ground the work pieces to be coated.
WARNING