7.2.3 DECOMMISSIONING AND CLEANING
7.3 LONGTERM STORAGE
7. Put the whole system back together.
8. Check the level of the separating agent -> Chapter 6.5.2.
9. Fill the system with  ushing agent as laid down in Chapter 7.1 "Filling with Working
Material".
Notice
The device should be cleaned for maintenance purposes. Ensure that no remaining
material dries and sticks.
Procedure:
1. Work interruptions -> carry out the steps in Chapter 7.2.2.
2. Carry out the basic  ushing -> Chapter 6.5.3.
3. Maintain the gun according to the operating manual.
4. Clean and check the suction system and the suction  lter.
5. When using a high pressure  lter: clean and check  lter insert and  lter housing.
6. Clean the outside of the system.
Brittle  lter pressure regulator!
The container on the  lter pressure regulator becomes brittle
through contact with solvents and can burst.
Flying parts can cause injury.
Do not clean the container on the  lter pressure regulator with
solvents.
WARNING
Gas mixtures can explode if there is an incompletely filled
pump!
Danger to life from flying parts.
Ensure that the pump and suction system are always completely
filled with  ushing agent or working medium.
Do not spray the device empty after cleaning.
WARNING
When storing the device for longer periods of time, it is necessary to thoroughly clean it
and protect it from corrosion. Replace the water or separating agent in the material pump
with a suitable preservative,  ll separating agent cup with separating agent.
Procedure:
1 Carry out points 1 through 9 in Chapter 7.2.3 "Decommissioning and Cleaning".
2 Flushing with preserving  uid according to Chapter 6.5.3.