9 MAINTENANCE
1. Check the level of separating agent in the separating agent cup every day, and top
up if necessary.
2. Check and clean the high pressure  lter every day or as required.
3. Every shut down should be carried out as laid down in Chapter 7.2.3!
4. Check hoses, pipes and couplings every day and replace if necessary.
In accordance with the guideline for liquid emitters (ZH 1/406 and BGR500 Part2
Chapter 2.36):
- The liquid emitters should be checked by an expert (e.g. Wagner service technician)
for their safe working conditions as required and at least every 12 months.
- For shut down devices, the examination can be suspended until the next start-up.
The service instructions are available in German and English.
Order number see Chapter 1.
Incorrect maintenance/repair!
Danger to life and equipment damage.
Only a WAGNER service center or a suitably trained person may
carry out repairs and replace parts.
Only repair and replace parts that are listed in the "Spare Parts"
chapter and that are assigned to the device.
Before all work on the device and in the event of work
interruptions:
- Disconnect the control unit from the mains.
- Relieve the pressure from the spray gun and device.
- Secure the spray gun against actuation.
Observe the operating and service instructions at all times when
carrying out work.