22 BlueCool S-Series
9 Commissioning
9.1 Check connections
Check all connections:
Check the electrical connections for firm seating.
Check that the sea water piping is firmly mounted and not lea-
king.
Check that the air ducts are firmly mounted and not leaking.
The air inlet and outlet air grilles must not be blocked.
9.2 Checking operation of condensed-wa-
ter drain
Pour water into the condensed-water tray and ensure correct
drainage.
The drain must be clear
Connections sealed
9.3 Filling sea water pump head
Self-priming sea water pumps:
Fill pump head with water.
9.4 Test run
Connect the power supply as shown in the wiring diagram.
Switch on the generator if necessary.
Switch on the self-contained air-conditioning unit in cooling
mode.
See Chapter “7 Operation” on page 17
Check the sea water flow rate.Determine the flow rate of the
exiting sea water with catch containers and a stop watch.
Note
The actual flow rate must be above the required min-
imum flow rate (see Chapter “13 Technical Data” on
page 30) to ensure fault-free operation at high sea
water temperatures.
If the minimum value is not reached, the pressure
losses in the sea water system should be reduced us-
ing the following measures:
Use larger cross-sections
fewer bends
shorter lines
use a more powerful pump

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Webasto S16-R-115V-REV-R410a and is the answer not in the manual?

Webasto S16-R-115V-REV-R410a Specifications

General IconGeneral
BrandWebasto
ModelS16-R-115V-REV-R410a
CategoryMarine Equipment
LanguageEnglish

Related product manuals