10.4 Checklist for inspection and maintenance
Maintenance task
Date:
1
Check the air filter on the evaporator and clean if
necessary.
See Chapter “10.1 Air filter” on page 23 and Fig.
4, No. 5
2
Check the flow rate of the sea water circuit at the
sea water outlet.
See Cahpter “10.2 Sea water circuit” on page 23
and Fig. 7 , no. 6
3
Check and clean the sea water strainer. Refer to the
filter manufacturer's specifications.
See Chapter “10.2 Sea water circuit” on page 23
and Fig. 7 , no. 2.
4
Check the entire sea water circuit for leaks.
See Chapter “10.2 Sea water circuit” on page 23
and Fig. 7.
5
Check the condensate outflow from the con-
densed-water tray and the condensed-water drain
line for free passage and leaks.
See Chapter “9.2 Checking operation of con-
densed-water drain” on page 22.
6
Clean the sea water circuit.
See Chapter “10.2 Sea water circuit” on page 23.
7
Check the electrical connections for corrosion to the
contacts and firm seating.
See Chapter “10.3 Electrical wiring” on page 23
and Fig.18.
8
Check the shaft seal of the sea water pump and re-
place it if necessary (does not apply to magnetically
coupled pumps).