TRC66-86 *** 37
3.3.3 Cleaning/Replacing the Air Filter
Cartridge
Important!
The air filter cartridge needs to be cleaned/replaced
only when the air filter service indicator light goes
on.
- Put the compactor out of operation as described in
paragraph 2.9.
- Open the maintenance door (8/1).
- Loosen the clamps (9/1) and remove the cover (10/1)
from the air filter body.
- Take out the air filter cartridge (11/1).
- Knock out the filter cartridge (11/1) or blow it clean with
compressed air (at a maximum pressure of 5 bar).
Caution!
If this method does not provide sufficient cleaning
(for example because of moist or oily dirt), a new
filter cartridge must be used.
- Insert the air filter cartridge (10/2).
- Put the cover (9/2) on the air filter body and firmly close
it with the clamps (9/1).
- Close the maintenance door (8/1).
Figure 8
Figure 9
Figure 10
Figure 11