EasyManuals Logo

WEG MVW3000 User Manual

WEG MVW3000
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
5
DETAILED PARAMETER DESCRIPTION
P0244 - Analog input AI3 offset (bipolar EBB board)
Adjustable range: -100.0 to 100.0 % Factory setting: 0.0 %
Acesso: Menu Configurations I/O Analog inputs
Description:
Refer to P0234.
P0245 - Analog input AI4 gain (bipolar EBA board)
Adjustable range: 0.000 to 9.999 Factory setting: 1.000
Acesso: Menu Configurations I/O Analog inputs
Description:
Refer to P0234.
NOTE!
Analog Input located on the EBA Optional Board. Refer to the Chapter 7 OPTIONAL ACCESSORIES
AND BOARDS on page 7-1 of the User’s Manual.
P0246 - AI4 Signal Type
Adjustable range: 0 to 4 Factory setting: 0
Acesso: Menu Configurations I/O Analog inputs
Description:
Set the S2.1 switch on the EBB optional board to “ON” position when a current signal is used at the analog
input AI4.
Inverse reference is obtained with the options 2 and 3, i.e., the maximum speed is obtained with the minimum
reference.
Table 5.42: AI4 Signal Type
P0246 Function
0
(0 to 10) V/(0 to 20) mA
1
(4 to 20) mA
2
(10 to 0) V/(20 to 0) mA
3
(20 to 4) mA
4
(-10 to +10) V
NOTE!
This parameter can be changed only with the motor stopped.
P0247 - Analog input AI4 offset (bipolar EBA board)
Adjustable range: -100.0 to 100.0 % Factory setting: 0.0 %
Acesso: Menu Configurations I/O Analog inputs
Description:
Refer to P0234.
MVW3000 | 5-49

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the WEG MVW3000 and is the answer not in the manual?

WEG MVW3000 Specifications