EasyManuals Logo

WEG MVW3000 User Manual

WEG MVW3000
264 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
7
DIAGNOSTICS AND TROUBLESHOOTING
Fault/alarm Reset Possible causes
F0351
Number of programmed cells
exceeds the inverter capacity
Power-on.
Manual (
O
/RESET key).
Auto-reset.
It resets automatically after the cause is
eliminated.
DIx.
Networks.
The total number of cells resulting from the in-
verter configuration exceeds the communication
capacity of the control rack; such number should
be fewer than 36 cells.
Invalid inverter configuration considering the
setting of parameters: Inverter rated volt-
age (P0296), Number of redundant cells per
phase (P1565) and Cells in parallel (P1892).
F0359
Timeout in the communication with
the thermal protection relay
Power-on.
Manual (
O
/RESET key).
Auto-reset.
DIx.
Networks.
P0315 > 0 and the cable for communication with
the thermal protection relay disconnected or de-
fective for more than 10 s.
A0360
Fault in the temperature sensor of
the thermal protection relay CH1
Power-on.
Manual (
O
/RESET key).
Auto-reset.
It resets automatically after the cause is
eliminated.
DIx.
Networks.
Temperature sensor broken wire.
PT100 accessory connectors disconnected.
Temperature channel active without a sensor
connected to the PT100 accessory.
A0361
Fault in the temperature sensor of
the thermal protection relay CH2
Power-on.
Manual (
O
/RESET key).
Auto-reset.
It resets automatically after the cause is
eliminated.
DIx.
Networks.
Temperature sensor broken wire.
PT100 accessory connectors disconnected.
Temperature channel active without a sensor
connected to the PT100 accessory.
A0362
Fault in the temperature sensor of
the thermal protection relay CH3
Power-on.
Manual (
O
/RESET key).
Auto-reset.
It resets automatically after the cause is
eliminated.
DIx.
Networks.
Temperature sensor broken wire.
PT100 accessory connectors disconnected.
Temperature channel active without a sensor
connected to the PT100 accessory.
A0363
Fault in the temperature sensor of
the thermal protection relay CH4
Power-on.
Manual (
O
/RESET key).
Auto-reset.
It resets automatically after the cause is
eliminated.
DIx.
Networks.
Temperature sensor broken wire.
PT100 accessory connectors disconnected.
Temperature channel active without a sensor
connected to the PT100 accessory.
A0364
Fault in the temperature sensor of
the thermal protection relay CH5
Power-on.
Manual (
O
/RESET key).
Auto-reset.
It resets automatically after the cause is
eliminated.
DIx.
Networks.
Temperature sensor broken wire.
PT100 accessory connectors disconnected.
Temperature channel active without a sensor
connected to the PT100 accessory.
A0365
Fault in the temperature sensor of
the thermal protection relay CH6
Power-on.
Manual (
O
/RESET key).
Auto-reset.
It resets automatically after the cause is
eliminated.
DIx.
Networks.
Temperature sensor broken wire.
PT100 accessory connectors disconnected.
Temperature channel active without a sensor
connected to the PT100 accessory.
MVW3000 | 7-9