QUICK REFERENCE OF PARAMETERS AND FAULTS
Param. Description Adjustable range Factory
setting
Page
P1079 Temperature on the power module of
cell W6
Read-only parameter (
C) - 5-100
P1080 Temperature on the power module of
cell W7
Read-only parameter (
C) - 5-100
P1081 Temperature on the power module of
cell W8
Read-only parameter (
C) - 5-100
P1082 Temperature on the power module of
cell W9
Read-only parameter (
C) - 5-100
P1083 Temperature on the power module of
cell W10
Read-only parameter (
C) - 5-100
P1084 Temperature on the power module of
cell W11
Read-only parameter (
C) - 5-100
P1085 Temperature on the power module of
cell W12
Read-only parameter (
C) - 5-100
P1136 Inverter input current Read-only parameter (A) - 5-100
P1137 Inverter input line voltage Read-only parameter (kV) - 5-100
P1138 PF at the inverter input - - 5-100
P1139 Apparent power at the inverter input Read-only parameter (kVA) - 5-101
P1140 Active power at the inverter input Read-only parameter (kW) - 5-101
P1141 Reactive power at the inverter input Read-only parameter (kVAr) - 5-101
P1143 Measured inverter output voltage Read-only parameter (kV) - 5-102
P1144 Voltage between the virtual neutral of the
motor and the ground of the system
Read-only parameter (%) - 5-102
P1155 Phase U cell status U1 ... Un - - 5-102
P1156 Phase V cell status V1...Vn - - 5-102
P1157 Phase W cell status W1...Wn - - 5-102
P1350 Temperature on the board of cell U1 Read-only parameter (
C) - 5-102
P1351 Temperature on the board of cell U2 Read-only parameter (
C) - 5-102
P1352 Temperature on the board of cell U3 Read-only parameter (
C) - 5-102
P1353 Temperature on the board of cell U4 Read-only parameter (
C) - 5-102
P1354 Temperature on the board of cell U5 Read-only parameter (
C) - 5-102
P1355 Temperature on the board of cell U6 Read-only parameter (
C) - 5-102
P1356 Temperature on the board of cell U7 Read-only parameter (
C) - 5-102
P1357 Temperature on the board of cell U8 Read-only parameter (
C) - 5-102
P1358 Temperature on the board of cell U9 Read-only parameter (
C) - 5-102
P1359 Temperature on the board of cell U10 Read-only parameter (
C) - 5-102
P1360 Temperature on the board of cell U11 Read-only parameter (
C) - 5-102
P1361 Temperature on the board of cell U12 Read-only parameter (
C) - 5-102
P1362 Temperature on the board of cell V1 Read-only parameter (
C) - 5-103
P1363 Temperature on the board of cell V2 Read-only parameter (
C) - 5-103
P1364 Temperature on the board of cell V3 Read-only parameter (
C) - 5-103
MVW3000 | 1-26