EasyManua.ls Logo

Wega Concept - Autosteamer system operation

Wega Concept
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
Wegaconcept
Technical manual
ENGLISHOperation
A
H
G
C
E
D
I
J
F
B
i
The system includes a time limit of 4 minutes
maximum for the autosteamer operation.
i
To change the temperature of the autosteamer,
and to enable or disable its operation, contact the
technical support.
!
To keep the steam dispensers in perfect working
order, it is advisable to carry out a brief dry delivery
after each use. Keep the tips of the autosteamer
clean at all times using a cloth dampened in
lukewarm water. If regular cleaning is not carried
out, the proper operation of the autosteamer can
be compromised.
!
Do not leave the autosteamer nozzle immerged
in the milk when it is not being used. Handle the
autosteamer with utmost caution due to the hazard
resulting from the presence of high-temperature
steam.
15.6 Autosteamer system operation
Below is listed the operating principle of the
autosteamer:
press the
or key;
opening of the solenoid valve ( A) with consequent
ow of steam from the boiler to the autosteamer;
simultaneously, the system activates the air pump
(E) which is controlled by the control unit (B) and
powered by a processor (G). The regulation of milk
foaming can be made by changing the amount of
air intake from the nozzle (F) using the control (D) as
indicated in par. 15.2;
after passing through the non-return valve ( C), the
air mixes with the steam in the "autosteamer inter-
face" (J);
leakage of steam from the pipe ( H);
the probe ( I) connected to the electronic unit of the
machine detects the temperature of the heating
milk;
Once the set temperature of the milk has been
reached, the electronic system blocks the  ow of air
and steam.