45
Wegaconcept
Technical manual
ENGLISHProgramming
23.12 Softener regeneration
To automatically display the message indicating the
need to regenerate the softener, proceed as follows:
ENTER
(x 5 secs.)
Hold down the ENTER button for at least 5 seconds.
Scroll the menu until the item is highlighted
09 FILTER REGENERAT.
10 COUNTERS
11 CLOCK SETUP
12 WORKING DAYS
ENTER Con rm to access the menu
REGENER. SOFTENER
XXXXX
Set the number of litres used by the machine after
which the message indicating the need for regenera-
tion will be shown
ENTER Con rm to exit the menu.
09 FILTER REGENERAT.
10 COUNTERS
11 CLOCK SETUP
12 WORKING DAYS
To exit the programming menu
23.13 Display of the counters
To display the work carried out by the machine (single
selections or total) and the number of doser alarms that
have occurred, proceed as follows:
ENTER
(x 5 secs.)
Hold down the ENTER button for at least 5 seconds.
Scroll the menu until the item is highlighted
09 FILTER REGENERAT.
10 COUNTERS
11 CLOCK SETUP
12 WORKING DAYS
ENTER Con rm to access the menu
TOTAL COFFEE
XXXXX
The rst screen shows the number of total co ee selec-
tions made by the machine.
To display the partial strokes for the various types of
delivery, press the respective keys on the push-button
panel. The selected key will light up, and the number of
selections made will be displayed.
COUNTERS
XXXXX
Press (), to view the number of doser alarms.
DOSER ALARMS
XXXX XXXX XXXX XXXX
ENTER Con rm to exit the menu.
09 FILTER REGENERAT.
10 COUNTERS
11 CLOCK SETUP
12 WORKING DAYS
To exit the programming menu
i
Once the set number of litres is reached, to stop the
signal on the display see chapter 27. To cancel the
signal set the litres to "000000".
i
To reset the counter alarms, see chapter 25.