44
Wegaconcept
Technical manual
23.11 Autosteamer option
To enable or disable the autosteamer, proceed as
follows:
The 3 temperature values (T1,T2 and T3) can be
programmed singularly and refer to the 3 functions on
the autosteamer keyboard:
ENTER
(x 5 secs.)
Hold down the ENTER button for at least 5 seconds.
Scroll the menu until the item is highlighted
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE
ENTER Con rm to access the menu
AUTOSTEAMER
YES/NO
Enable or disable the autosteamer (if you select NO, the
"Autosteamer" keyboard will be excluded).
If activated, press (), to view the programming
temperature for each di erent function.
AUTOSTEAMER (.C)
T1=XX T2=XX T3=XX
Set the desired temperature (50 ÷ 80 °C).
Press the () and () keys to switch from a value to
another.
ENTER Con rm to exit the menu.
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE
To exit the programming menu
AUTO
With this mode you can set the number of dispensed
beverages in one hour; below that value the system
places each delivery group in stand-by (little work).
Once confirmed and exited from the menu, the
machine should be turned o and back on pressing
the ENTER button, until the message "TEST OK" is
displayed.
From now on, a one-week period of machine
monitoring begins.
Press (), to visualize the stand-by late minutes
STAND-BY DELAY
MN
ENTER Con rm to exit the menu.
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE
To exit the programming menu
press (), to view the number of possible beverages
AUTOMATIC STAND-BY
THRESHOLD
XX
ENTER Con rm to exit the menu.
05 ENERGY SAV TIME
06 PROPER USE
07 STBY MODE
08 MODE AUTOSTEAMER
To exit the programming menu
T1. T2. T3.