44
Wegaconcept
Technical manual
23.11 Autosteamer option
To enable or disable the autosteamer, proceed as
follows:
The 3 temperature values (T1,T2 and T3) can be
programmed singularly and refer to the 3 functions on
the autosteamer keyboard:
ENTER
(x 5 secs.)
Hold down the ENTER button for at least 5 seconds.
Scroll the menu until the item is highlighted
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE
ENTER Con rm to access the menu
AUTOSTEAMER
YES/NO

Enable or disable the autosteamer (if you select NO, the
"Autosteamer" keyboard will be excluded).
If activated, press (), to view the programming
temperature for each di erent function.
AUTOSTEAMER (.C)
T1=XX T2=XX T3=XX

Set the desired temperature (50 ÷ 80 °C).

Press the () and () keys to switch from a value to
another.
ENTER Con rm to exit the menu.
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE

To exit the programming menu
AUTO
With this mode you can set the number of dispensed
beverages in one hour; below that value the system
places each delivery group in stand-by (little work).
Once confirmed and exited from the menu, the
machine should be turned o and back on pressing
the ENTER button, until the message "TEST OK" is
displayed.
From now on, a one-week period of machine
monitoring begins.
Press (), to visualize the stand-by late minutes
STAND-BY DELAY
MN
ENTER Con rm to exit the menu.
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE

To exit the programming menu
press (), to view the number of possible beverages
AUTOMATIC STAND-BY
THRESHOLD
XX
ENTER Con rm to exit the menu.
05 ENERGY SAV TIME
06 PROPER USE
07 STBY MODE
08 MODE AUTOSTEAMER

To exit the programming menu
T1. T2. T3.

Table of Contents