30
Wegaconcept
Technical manual
Cleaning
Daily
Weekly
Monthly
BODY
Clean the panels of the body with a cloth dampened
in lukewarm water. Do not use abrasive detergents
which may scratch the surface of the body.
X
PERFORATED DISK and
CONTAINMENT RING
Loosen the screw (A) and
remove the perforated
disk (B) and containment
ring (C) from the delivery
group. Wash with hot water.
X
DISPENSER UNIT
Carry out the washing of the groups as indicated in
Chapter 17 and follow the instructions below:
use the solid lter holder;•
pour the detergent on the solid lter and attach •
the lter holder;
carry out a series of deliveries until the water •
comes out clean;
remove the lter holder from the unit and carry •
out at least one delivery so as to eliminate any
detergent residues.
X
GRINDER-DOSER
Clean the inside and outside of the receptacle and
doser of the grinder-doser with a cloth dampened
in lukewarm water.
X
C
B
A
19 Checks and maintenance
To ensure perfect safety and e ciency of the machine
over time, it is necessary to carry out maintenance. In
particular, it is advisable to carry out an overall check
of the machine at least once a year.
Checks
Weekly
Monthly
Yearly
MACHINE
Using the machine display, check that the indicated •
pump pressure is around 8-9 bar.
Check that the boiler pressure indicated on the •
display is consistent with a programming value.
X
FILTER HOLDER FILTERS
Check the wear of the lters, if there is damage to
the edges, and if co ee grounds are getting into the
cup. If necessary, replace the lters.
X
GRINDER-DOSER
Check the dose of the ground co ee, which should •
be about 6-7 gr. at a time, and adjust the amount
as necessary.
Check the degree of grinding and modify as •
required.
Check the grinders for wear: they should be re-•
placed if there is too much powder in the ground
co ee.
You should replace the at grinders after every •
400/500 kg of co ee. For conical grinders, replace
every 1000/1200 kg
X
SOFTENER
Carry out regeneration of the softener (for the •
manual softener).
Check that there is salt in the container (for the •
softener in the automatic version).
X
!
During the cleaning operations, pay attention to •
the parts of the machine that are overheated.
To guarantee the correct operation and hygiene •
of the machine, it is necessary to use the
cleaning methods and products suitable for
the purpose.
Do not immerge the machine into water.•
Never use alkaline detergents, solvents, alcohol •
or aggressive substances.
The descaling of the machine has to be •
performed by dismounting the encrusted
components, so that no descaling debris is put
into circulation. The used products/detergents
have to be suitable for the purpose and must not
corrode the hydraulic circuits materials.