TECHNICIANS manual
Par. Description min Def MAX Um
P72 First timeout loading coee boiler 0 240 255 s
P73 Coee boiler lling timeout. 0 60 255 s
P74 Coee boiler lling second phase timeout. 0 120 255 s
P75
Coee delivery control mode:
0 0 3
0 = Null
1 =Timer
2 = Flow
3 = Temperature
P76 Maximum ow variation percentage 5 15 40
P77
Time out during dispensing for "coee water pres-
sure" warning
10 90 250 s
P78 Force end dispensing timeout (single dispensing) 10 120 250 s
P79
Minimum number of pulses to accept dose pro-
gramming
10 10 250 Pls
P80 Services boiler minimum pressure. 0 0 P81 bar
P81 Services boiler maximum pressure P80 1.4 2.5 bar
P82 Services boiler pressure setpoint. P80 1.2 P81 bar
P83
Services boiler minimum pressure for hot water
dispensing. 0 = Boiler disabled.
0 0.5 P82 bar
P84
Steam SV opening temperature with machine in
Energy Saving.
0 104 255 °C
P85
Pressure set due to steam SV closing and elimina-
tion of the steam release warning during steam
boiler loading phase (eq. P88 for the machine with
pressure transducer).
0 0.01 0.5 bar
P86 Services boiler level detection time lag 0 3 10 s
P87
Temperature set due to steam release warning during
steam boiler loading phase.
50 93 150 °C
P88
Temperature set due to steam solenoid valve closing
and elimination of the steam release warning during
steam boiler loading phase.
50 97 150 °C
P89
Steam SV opening pressure with machine in En-
ergy Saving (eq. P84 for the machine with pressure
transducer).
0 0.2 2 Bar
P90
Services boiler temperature threshold, below which
the analog pressure transducer must be ignored and
only the temperature must be considered.
50 97 150 °C
P91 Steam boiler heating Timeout (entry into P-band). 0 60 255 Min
P92 Steam boiler lling timeout. 0 45 255 s
P93 Steam boiler loading rst timeout 0 255 600 s
P94 Set services boiler in Energy Saving 50 80 P90 °C
P95
Delta temperature due to group heating timeout
alarm
0 10 20 °C
P96
Maximum duration continuous coee dispensing
(Start/Stop button)
10 120 600 s
P97 Set boiler pressure in boost P80 1.3 P81 bar
P98 Boost duration 0 30 600 min
P99 Boiler water replacement enabling parameter 0 0 1
P101 Autosteamer temperature T1 set 50 55 80 °C
P102 Set Temperature T2 Autosteamer 50 65 80 °C
P103 Set Temperature T3 Autosteamer 50 65 80 °C
P104 Autosteamer dispensing timeout. 0 240 600 s
P105
Time window after dispensing with Autosteamer to
continue manual dispensing.
0 3 30 s
P106 Set cup-warmer temperature P108 80 P109 °C
P107 Cup warmer regulation dierential 0 0.1 10 °C
P108 Cup-warmer minimum temperature. 0 70 P109 °C
P109 Cup-warmer maximum temperature. P108 100 120 °C
Par. Description min Def MAX Um
P110
Threshold for grinder wear indication.
0 0 2000 kg
0 = disabled.
P111 Short coee weight (for grinder wear) 0 0 22 g
P112 Medium coee weight (for grinder wear) 0 0 22 g
P113 Long coee weight (for grinder wear) 0 0 22 g
P114 Double short coee weight (for grinder wear). 0 0 22 g
P115 Double medium coee weight (for grinder wear). 0 0 22 g
P116 Double long coee weight (for grinder wear). 0 0 22 g
P117 Continuous coee weight (for grinder wear). 0 0 22 g
P120 Service required threshold A. 0 0
1000000
cycles
P121 Service required threshold B. 0 0
1000000
cycles
P122 Service required threshold C. 0 0
1000000
cycles
P123 Delta cycles for assistance request. 0 1000
10000
cycles
P125 Set card temperature warning 0 65 90 °C
P126 Set alarm card temperature 0 70 90 °C
P127 Temperature dierential for resumption from alarm 10 15 30 °C
P130 Threshold for regeneration. 0 0
10000
L
P131
Amount of water per second to be added to the count
of the water liters consumed by the machine when
the ller SV is open.
0 21 255 ml/s
P132
Amount of water per second to be added to the count
of the water liters consumed by the machine when
the mix SV is open.
0 8 255 ml/s
P133
Delay from the last beverage made for entry into
standby.
0 10 255 min
P134
Threshold hourly deliveries for entry into automatic
standby
1 5 250
P135
Energy saving type
0 0 2
0 = Only group manual O
1 = Timer management
2 = Automatic self-learning
P136
Weight for calculating auto mode average (operates
on old value)
1 5 10
P137
Pre-setting the number of coees dispensed within
10 minutes for auto mode dispensing history (initial
value of the reference)
0 10 255
P138 First group to be switched on in AUTO mode 0 0 4
P139 Second group to be switched on in AUTO mode 0 0 4
P140 Third group to be switched on in AUTO mode 0 0 4
P141 Group 1 temperature display 0 0 2
P142 Group 2 temperature display 0 0 2
P143 Group 3 temperature display 0 0 2
P144 Group 4 temperature display 0 0 2
P145 Washing groups - Number washing cycles 1 5 10
P146 Washing groups - Rinse time 10 30 100 s
P147
Hours to wait before re-proposing washing upon
power on
0 24 48 hours
P148 Automatic washing time 0 0 1
P150
Coee boiler, group, and services boiler PID cycle
time.
0.5 10 10 s
P152 Coee group PID proportional band 0.1 5 100.0 °C
P153 Coee groups PID integrative coecient 0 60
10000
s
P154 Coee groups PID derivative coecient 0 2.0 10.0 s
P156 Coee boiler PID proportional band 0.1 5.0 100.0 °C
P157 Coee boiler PID integrative coecient 0 60
10000
S

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wega MyConcept EVDP 2GR and is the answer not in the manual?

Wega MyConcept EVDP 2GR Specifications

General IconGeneral
BrandWega
ModelMyConcept EVDP 2GR
CategoryCoffee Maker
LanguageEnglish

Related product manuals