70 of 76
TECHNICIANS manual
Par. Description min Def MAX Um
P72 First timeout loading coee boiler 0 240 255 s
P73 Coee boiler lling timeout. 0 60 255 s
P74 Coee boiler lling second phase timeout. 0 120 255 s
P75
Coee delivery control mode:
0 0 3
0 = Null
1 =Timer
2 = Flow
3 = Temperature
P76 Maximum ow variation percentage 5 15 40
P77
Time out during dispensing for "coee water pres-
sure" warning
10 90 250 s
P78 Force end dispensing timeout (single dispensing) 10 120 250 s
P79
Minimum number of pulses to accept dose pro-
gramming
10 10 250 Pls
P80 Services boiler minimum pressure. 0 0 P81 bar
P81 Services boiler maximum pressure P80 1.4 2.5 bar
P82 Services boiler pressure setpoint. P80 1.2 P81 bar
P83
Services boiler minimum pressure for hot water
dispensing. 0 = Boiler disabled.
0 0.5 P82 bar
P84
Steam SV opening temperature with machine in
Energy Saving.
0 104 255 °C
P85
Pressure set due to steam SV closing and elimina-
tion of the steam release warning during steam
boiler loading phase (eq. P88 for the machine with
pressure transducer).
0 0.01 0.5 bar
P86 Services boiler level detection time lag 0 3 10 s
P87
Temperature set due to steam release warning during
steam boiler loading phase.
50 93 150 °C
P88
Temperature set due to steam solenoid valve closing
and elimination of the steam release warning during
steam boiler loading phase.
50 97 150 °C
P89
Steam SV opening pressure with machine in En-
ergy Saving (eq. P84 for the machine with pressure
transducer).
0 0.2 2 Bar
P90
Services boiler temperature threshold, below which
the analog pressure transducer must be ignored and
only the temperature must be considered.
50 97 150 °C
P91 Steam boiler heating Timeout (entry into P-band). 0 60 255 Min
P92 Steam boiler lling timeout. 0 45 255 s
P93 Steam boiler loading rst timeout 0 255 600 s
P94 Set services boiler in Energy Saving 50 80 P90 °C
P95
Delta temperature due to group heating timeout
alarm
0 10 20 °C
P96
Maximum duration continuous coee dispensing
(Start/Stop button)
10 120 600 s
P97 Set boiler pressure in boost P80 1.3 P81 bar
P98 Boost duration 0 30 600 min
P99 Boiler water replacement enabling parameter 0 0 1
P101 Autosteamer temperature T1 set 50 55 80 °C
P102 Set Temperature T2 Autosteamer 50 65 80 °C
P103 Set Temperature T3 Autosteamer 50 65 80 °C
P104 Autosteamer dispensing timeout. 0 240 600 s
P105
Time window after dispensing with Autosteamer to
continue manual dispensing.
0 3 30 s
P106 Set cup-warmer temperature P108 80 P109 °C
P107 Cup warmer regulation dierential 0 0.1 10 °C
P108 Cup-warmer minimum temperature. 0 70 P109 °C
P109 Cup-warmer maximum temperature. P108 100 120 °C
Par. Description min Def MAX Um
P110
Threshold for grinder wear indication.
0 0 2000 kg
0 = disabled.
P111 Short coee weight (for grinder wear) 0 0 22 g
P112 Medium coee weight (for grinder wear) 0 0 22 g
P113 Long coee weight (for grinder wear) 0 0 22 g
P114 Double short coee weight (for grinder wear). 0 0 22 g
P115 Double medium coee weight (for grinder wear). 0 0 22 g
P116 Double long coee weight (for grinder wear). 0 0 22 g
P117 Continuous coee weight (for grinder wear). 0 0 22 g
P120 Service required threshold A. 0 0
1000000
cycles
P121 Service required threshold B. 0 0
1000000
cycles
P122 Service required threshold C. 0 0
1000000
cycles
P123 Delta cycles for assistance request. 0 1000
10000
cycles
P125 Set card temperature warning 0 65 90 °C
P126 Set alarm card temperature 0 70 90 °C
P127 Temperature dierential for resumption from alarm 10 15 30 °C
P130 Threshold for regeneration. 0 0
10000
L
P131
Amount of water per second to be added to the count
of the water liters consumed by the machine when
the ller SV is open.
0 21 255 ml/s
P132
Amount of water per second to be added to the count
of the water liters consumed by the machine when
the mix SV is open.
0 8 255 ml/s
P133
Delay from the last beverage made for entry into
standby.
0 10 255 min
P134
Threshold hourly deliveries for entry into automatic
standby
1 5 250
P135
Energy saving type
0 0 2
0 = Only group manual O
1 = Timer management
2 = Automatic self-learning
P136
Weight for calculating auto mode average (operates
on old value)
1 5 10
P137
Pre-setting the number of coees dispensed within
10 minutes for auto mode dispensing history (initial
value of the reference)
0 10 255
P138 First group to be switched on in AUTO mode 0 0 4
P139 Second group to be switched on in AUTO mode 0 0 4
P140 Third group to be switched on in AUTO mode 0 0 4
P141 Group 1 temperature display 0 0 2
P142 Group 2 temperature display 0 0 2
P143 Group 3 temperature display 0 0 2
P144 Group 4 temperature display 0 0 2
P145 Washing groups - Number washing cycles 1 5 10
P146 Washing groups - Rinse time 10 30 100 s
P147
Hours to wait before re-proposing washing upon
power on
0 24 48 hours
P148 Automatic washing time 0 0 1
P150
Coee boiler, group, and services boiler PID cycle
time.
0.5 10 10 s
P152 Coee group PID proportional band 0.1 5 100.0 °C
P153 Coee groups PID integrative coecient 0 60
10000
s
P154 Coee groups PID derivative coecient 0 2.0 10.0 s
P156 Coee boiler PID proportional band 0.1 5.0 100.0 °C
P157 Coee boiler PID integrative coecient 0 60
10000
S