IE-SW-VL08M Series User’s Manual Featured Functions
3-63
Setting Description Factory Default
Disable/Enable to
change Password
To reset the Password from the Web
Browser interface, click the Change
password check-box, type the Old
Password, type the New Password, retype
the New password, and then click Activate.
The password can be a maximum of 45
characters.
Disable
Old Password Type the current password when changing
the password
None
New Password Type new password when enabled to change
password. The password can be a maximum
of 45 characters.
None
Retype Password If you type a new password in the Password
field, you will be required to retype the
password in the Retype new password field
before updating the new password.
None
Email Address
Setting Description Factory Default
Max. 30 Characters
You can set up to 4 email addresses to
receive warning emails from the
IE-SW-VL08M.
None
Send Test Email
After finishing with the email settings, you should first press the Activate button to activate those
settings, and then press the Send Test Email button to verify that the settings are correct.
NOTE
Auto warning e-mail messages will be sent through an authentication protected SMTP server that
supports the CRAM-MD5, LOGIN, and PAIN methods of SASL (Simple Authentication and
Security Layer) authentication mechanism.
We strongly recommend not entering your Account Name and Account Password if auto warning
e-mail messages can be delivered without authentication mechanism.
Configuring Relay Warning
The Auto Relay Warning function uses relay output to alert the user when certain user-configured
events take place. There are two basic steps required to set up the Relay Warning function:
1. Configuring Relay Event Types
Select the desired Event types from the Console or Web Browser Event type page (a
description of each event type is given later in the Relay Warning Events setting subsection).
2. Activate your settings
After configuring, you will need to activate your Weidmueller switch’s Relay Event Types.