IE-SW-VL08M Series User’s Manual Featured Functions
3-74
Using Event Log
Bootup
This field shows how many times the IE-SW-VL08M
has been rebooted
or cold started.
Date
The date is updated based on how the current date is set in the “Basic
Setting” page.
Time
The time is updated based on how the current time is set in the “Basic
Setting” page.
System Startup Time The system startup time related to this event.
Events Events that have occurred.
Events are logged in the IE-SW-VL08M Event Log when the following events occur:
1. Cold start
2. Warm start
3. Configuration Change Activated
4. Power Transition from OFF to ON or from ON to OFF
5. Authentication Fail
6. Topology Changed
7. Master Setting is Mismatched
8. Port Traffic Overload
9. Port Link from OFF to ON or from ON to OFF
Using Syslog
This function provides the event logs for the syslog server. The function supports 3 configurable
syslog servers and syslog server UDP port numbers. When an event occurs, the event will be sent as
a syslog UDP packet to the specified syslog servers.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Weidmüller IE-SW-VL08M Series and is the answer not in the manual?

Weidmüller IE-SW-VL08M Series Specifications

General IconGeneral
BrandWeidmüller
ModelIE-SW-VL08M Series
CategoryNetwork Router
LanguageEnglish

Related product manuals