3. Do one of the following in double-axis mode according to the actual situation:
– If it is the first time to execute tool calibration, press F7.
– After tool change or tool break, press F2.
The system automatically records the calibration results into the tool offset.
Note: Calibration after tool changed must be executed after completion of first-time calibration.
4 FAQs
Through this section, you can know the following frequently asked questions by
manufacturers during use, and their corresponding causes and solutions for
troubleshooting.
• Axis servo alarm.
• Failed to register the system.
• Drive 400 alarm.
If the solution does not work or you have any other questions, please contact with
our sales engineers.
4.1 Axis Servo Alarm
Cause
1. Polarity error in port Axis Servo Alarm.
2. An alarm on the servo drive.
Solution
1. Press → 3 to enter Port interface and adjust polarity of the
corresponding port.
2. Check the servo connecting wire of each axis.